NDTVDC93

модель:
NDTVDC93 
двигун:
DC09 320A 02-63 
Зробити:
SCANIA 
Охолодження:
вода 
Циліндри:
Водотоннажність:
9300
Потужність PRP:
300 [кВА]
Потужність LTP:
330 [кВА]
Електричні характеристики:
400/230 V+N 
RPM:
1500 

COELMO® Manual Control Panels are designed and realized in a way to unite a unique command system, the controls and the protections of the Generating Sets avoid breakdowns caused by of lack of oil and high engine temperature.

Realized in zinc plated steel painted in epoxy powder with a minimum protection grade of IP30 (on request they can be supplied separately), they are protected from the vibrations created by the Generating Set by isolating blocks.

A magneto-thermal 3 pole circuit breaker (4 pole on request) guarantees the electrical protection of the COELMO® Generating Set.

Upon request, a wide range of accessories can be applied to the Manual Control panel according to the end user's needs.

 
giotto
 
 
ELECTRICAL MEASURES
 
Line voltage
Star voltage
Frequency
Current on load
 
GENERATING SET PARAMETRES
 
Rated speed
Battery voltage
Hour counter
Starter counter
 
ACCESSORIES
 
Circuit breaker with key
Emergency button
Number of inlets dedicated
6
Number of programmable inlets
4
Number of outlets dedicated
2
Number of programmable outlets
4
 
OPERATIVE MODES
 
Manual
Supermanual
 
ALLARMS
 
Oil Pressure
Engine over heating
Alternator over heating
Breakdown dynamo belt
Lackage of fuel
Insufficient battery load
Over load
Short circuit
Maintenance request
Low water level
Differential protection
 
MECHANICAL MEASURES
 
Oil pressure
Water temerature
Fuel level

COELMO® Automatic Control Panels allow to automatically receive the alimentation of the Generating Set within a few seconds from verification of a black out on the main electrical network. When the main electrical network returns to normal function, the COELMO® Automatic Control Panel will change over to the main electrical network's alimentation all the utilities connected. Functions of the Automatic Control Panel

- Automatic start up of Generating Set when the tension of the main electrical network varies from a pre-defined value (programmable);
- Automatic insertion of the Generating Set as main source of electrical energy as soon as the working parameters are reached;
- Verification of the engine paramiters and those of the alternator through special protections
- Automatic disengagement of the Generating Set from the utilities once the nominal tension of the mains is reached;
- Period of time to allow for the tension to stabilize;
- Programmed slow shut down of the Generating Set to allow the engine to cool down gradually;
- Predisposition for a new service;
- Battery charger to guarantee the correct efficiency of the battery and of the alimentation of the comand/control system;

The internal change over switch (optional) is realized with contactors mechanically and electrically internally blocked up to 250A and with motorized change over 1-0-2 higher than 250A.

 lexys
 
ELECTRICAL MEASURES
 
Line voltage
Star voltage
Frequency
Current on Load
Active Power
Apparent Power
Power Factor
Fuel Level
 
MECHANICAL MEASURES
 
Oil pressure
Differential Current
Water temerature
Oil Temperature
 
ALARMS
 
Oil pressure
Engine over heating
Alternator over heating
Breakdown dynamo belt
Lackage of fuel
Insufficient battery load
Over load
Short circuit
Maintenance request
Low water level
Differential protection
Differential Current
 
OPERATIVE MODES
 
Manual
Super manual
Automatic
Test
 
ACCESSORIES
 
Emergency button (on panel)
Number of inputs dedicated
7
9
8
Number of programmable inputs
4
4
8
Number of outputs dedicated
2
4
4
Number of programmable outputs
4
4
8
Number of analog inputs
3
3
4
Number of programmable inputs
4
Number of programmable analog outputs
2
Battery charger monitor
Electronic acoustic alarm
Programmable messages from PC
Historical Fault list
Memory Of Historical Events
Possbility of expansion
Detailed maintenace plan
Integrated PLC
Remote Display Interface
Pc Board 16 alamrs interface
Graphical Display
 
GENERATING SET PARAMETRES
 
Rated speed
Battery tension
Hour counter
Fuel Level
Total start-up counter
Failed start-up counter
Power active counter
Power reactive counter
Synchronoscope

 

Container

The ISO Standard Container 20”, 30” and 40” are designed to be used under any condition and transported by sea (above or below deck) or by land (roads and railways).

Versatile in the utilization, they constitute an alternative to the Sound proof canopies of KUBE series for the soundproofing of Coelmo® Generating Sets.

The noise breakdown is provided by fireproof insulating baffles with a sound level comply with Directive 2000/14/EC

Kontenery COELMO

COELMO Generating Sets & more

Do you have any questions?

We remain at your disposal! Write to us and one of COELMO's specialists will contact you shortly.